CCR1009-8G-1S-PC

  • $425.00

  • Ex Tax: $425.00
  • Availability:Out Of Stock
  • Product Code: CCR1009-8G-1S-PC


CCR1009-8G-1S-PC

Our popular 9-core Cloud Core Router is now available in a new passive cooling enclosure. This CCR1009 unit is equipped with two heat-pipes and a specially designed heat-sink, so its completely silent.

The unit is powered by an external 24v 2.5A AC/DC adapter and supports power redundancy if you also power it from the PoE input port.

Product specifications

Details
Product codeCCR1009-8G-1S-PC
CPU nominal frequency1 GHz
CPU core count9
Size of RAM1 GB
10/100/1000 Ethernet ports8
Number of USB ports1
Power Jack1
Supported input voltage14 V - 57 V
PoE inYes
Voltage MonitorYes
CPU temperature monitorYes
PCB temperature monitorYes
Dimensions272x190x47mm
Operating SystemRouterOS
Tested ambient temperature-20C .. +60C
License level6
Current MonitorYes
CPUTLR4-00980CG-10CE-A3a
SFP ports1
USB slot typemicroUSB type AB
Serial portRS232 + Header
Storage typeNAND
Storage size128 MB
Suggested price$425

Included parts

Ethernet test results

CCR1009-8G-1S-PCTile 9 core all port test 1GHz
ModeConfiguration1518 byte512 byte64 byte
kppsMbpskppsMbpskppsMbps
Bridgingnone (fast path)486.65909.31404.55,752.88725.34467.4
Bridging25 bridge filter rules486.45906.81129.24,625.21132.6579.9
Routingnone (fast path)487.65921.41405.45,756.58723.94466.6
Routing25 simple queues487.65921.41405.45,756.51566.7802.2
Routing25 ip filter rules487.65921.4620.12,539.9627.4321.2
  1. All tests are done with Xena Networks specialized test equipment (XenaBay),and done according to RFC2544 (Xena2544)
  2. Max throughput is determined with 30+ second attempts with 0,1% packet loss tolerance in 64, 512, 1518 byte packet sizes
  3. Values in Italic indicate that max throughput was reached without maxing out CPU, but because board interface configuration was maxed out
  4. Test results show device maximum performance, and are reached using mentioned hardware and software configuration, different configurations most likely will result in lower results